Thermic fluid heaters · 25+ years of experience · ISO 9001:2015 certifiedThermic fluid heater manufacturer · 25+ years of experience · ISO 9001:2015 certifiedHeaters built to your heat load – quote within one working dayMade in India · Ahmedabad works · Installation, commissioning & after-sales service

The heater guide

Thermic Fluid Heater – Working, Types & Selection

What a thermic fluid heater does, how it works, the types, the fuel options and how to size one – from the engineers who build them.

  • ISO 9001:2015 · TÜV certified
  • 25+ years · 3000+ customers
  • Engineered to your process

What is a thermic fluid heater?

A closed oil loop that carries heat to your process

A thermic fluid heater, also called an industrial thermic oil heater, is a closed-loop heating system that uses thermal oil as the heat-transfer fluid. A burner (or an electric element) heats the oil in a coil; a pump circulates it in a closed loop to your process and back, giving indirect heat with precise temperature control. Explore our thermic oil heater working principle guide for step-by-step coil flow and loop details.

Because the oil can run very hot without being pressurised, you avoid the high pressure of steam. The heater type, fuel, coil design and controls are chosen for your heat load and process – so two heaters that look alike can be very different machines. They are widely paired with indirect-heated process equipment such as paddle dryers, jacketed reactors, and calenders.

  • High, steady temperature at low pressure
  • Solid-fuel, oil, gas, electric or hybrid
  • Sized to your heat load, fuel and process

How it works

Fuel burns. Oil heats. Process runs.

  1. 1
    Fuel burns

    The burner fires fuel and air into the furnace. Hot flue gas passes over the heating coil.

  2. 2
    Oil takes the heat

    Thermic oil flows through the coil and picks up that heat – without boiling and without high pressure.

  3. 3
    Hot oil travels

    A circulation pump pushes the hot oil to your dryer, press, reactor or jacketed vessel.

  4. 4
    Heat is used, oil returns

    The oil gives its heat to the process and comes back cooler. An expansion tank takes up the oil's growth as it heats.

Our products

Thermic fluid heaters for every fuel and floor plan

Six heater types, each built to your heat load, oil temperature and process. Pick one to get a quote – or tell us your process and we will recommend the right one.

Horizontal thermic fluid heater

Horizontal shell-type coil. Easy to maintain, with a compact footprint.

Best for Plants with height restrictions

Get a quote

Vertical thermic fluid heater

Vertical coil in a cylindrical shell. Saves floor space and recovers heat well.

Best for Textile, food and pharma plants

Get a quote

Solid-fuel fired heater

Burns wood, coal, briquettes or agro-waste, so running costs stay low where that fuel is cheap.

Best for Textiles, plywood, rubber

Get a quote

Oil / gas fired heater

Runs on furnace oil, diesel, natural gas or LPG. Cleaner, more efficient and needs less manual work.

Best for Food, pharma, petrochemicals

Get a quote

Electric heater

Heats the oil with electricity. No emissions, so it suits clean rooms and pharma work. Running cost is higher where power is dear.

Best for Pharma, clean-room and small loads

Get a quote

Hybrid heater

Combines a solid-fuel and an oil/gas system. Switch fuels when supply or price changes.

Best for Plants with an unstable fuel supply

Get a quote

Fuel options

Oil, gas, solid fuel or electricity?

The fuel you can get, and what it costs, shapes the heater you should buy. Review our engineering guides for gas fired thermic fluid heaters and electric thermic fluid heaters alongside oil and solid-fuel units.

Diesel, furnace oil, LPG or natural gas

A burner fires the fuel automatically. Clean, steady and easy to control.

Good for Food, pharma, chemicals – where clean heat matters

Wood, coal, briquettes or agro-waste

Solid fuel keeps the running cost down where it is cheap and easy to get.

Good for Textile, plywood, rubber, rural plants

Electricity

Resistance elements heat the oil directly. No flue, no fuel storage, precise control.

Good for Clean rooms, laboratories, smaller loads

Inside the heater

The parts that decide how long it runs well

Tap the dots on the 3D heater at the top of the home page, or read them here.

1Burner & air fan

Fires oil, gas or solid fuel into the furnace. A good burner gives a steady flame and clean combustion.

2Double heating coil

Oil flows through two concentric coils. The inner coil faces the flame; the outer coil takes heat from the flue gas.

3Insulated shell

Keeps the heat in the furnace. Good insulation saves fuel and keeps the outside safe to stand near.

4Flue duct & chimney

Carries the cooled gas away. The lower the stack temperature, the less heat is wasted.

5Expansion tank

Sits above the heater. It takes up the oil's growth as it heats and keeps the pump from running dry.

6Circulation pump

Keeps a steady flow through the coils. Oil that keeps moving protects both the oil and the coil.

7Hot oil to process

Sends hot oil to your dryer, press, reactor or jacketed vessel – at low pressure, with no steam.

8Control panel

Sets the temperature and watches flame, oil flow and temperature. It trips the burner if something goes wrong.

Thermic fluid heater vs steam boiler

When steam is more trouble than it is worth

If your process needs high, steady heat but not steam itself, thermic oil is often the simpler route.

Steam boilerThermic fluid heater
Pressure at high temperatureRises with temperature – a pressure vesselStays low even when the oil is hot
Water treatmentNeeded – scale, corrosion and blowdownNone – closed oil loop
Temperature rangeLimited by the pressure you can runHigh: roughly 300 to 400 °C, depending on design and fluid
MaintenanceWater chemistry, blowdown, scaleMainly oil-quality checks and routine burner care
Heating styleSteam can heat directly or indirectlyIndirect – precise and even
Best forProcesses that use steam itselfContinuous heating at steady, high temperature

Fuel-cost calculator

What will your heater burn – and cost?

Move the slider, pick your fuel – see the heat needed, fuel per hour, a nearest heater size and the yearly fuel cost. 20 seconds.

0 kWuseful heat needed
Fuel burnt per hour
0 litre
Heat the fuel must supply
0 kcal/hr
Nearest standard heater size
0 kcal/hr
Fuel cost per year*
₹0
Get a heater sized for this load

*Indicative only. Fuel needed = heat load ÷ (fuel heat value × efficiency). Heat values used: diesel 8,500 kcal/litre, furnace oil 9,900 kcal/kg, natural gas 8,500 kcal/m³, LPG 11,000 kcal/kg, briquettes 4,000 kcal/kg, coal 5,000 kcal/kg, electricity 860 kcal/kWh. Real fuels vary – enter your own price and we will size the heater on your actual data.

Selection checklist

Six facts we need to size your heater

Do not worry if you do not have all of them. Send what you know – our engineers will help with the rest.

1Heat load

How much heat the process needs, in kcal/hr or kW – including the start-up load.

2Temperature

The oil temperature your process needs, and the temperature drop across it.

3Fuel

Diesel, furnace oil, gas, LPG, solid fuel or electricity – and what it costs you.

4Process

Dryer, press, reactor, jacketed vessel or heat exchanger – and how many points.

5Site

Space, height, chimney, ambient conditions and utilities.

6Controls

Manual or fully automatic, temperature profile, safety interlocks and remote monitoring.

FAQ

Technical questions

What is the maximum temperature a thermic fluid heater can reach?

High-quality thermic oil heaters can reach roughly 300 °C to 400 °C, depending on the design and the heat-transfer fluid used. The exact range depends on your process and the fluid specification.

How do I choose the right thermic fluid heater for my application?

Consider the required heat load, the temperature range, the fuel type (solid, gas, oil or electric), the type of application and the space available. An experienced manufacturer such as AS Engineers can help you select the right configuration.

What does the expansion tank do?

Thermal oil grows in volume as it heats. The expansion tank, placed above the heater, takes up that growth and keeps the pump supplied with oil. It also gives the system a place to vent light vapours safely.

What safety controls does a thermic fluid heater have?

Essential controls for oil temperature, oil circulation, flame monitoring, pressure and system protection. They trip the burner or heater if something goes wrong, so the plant and people stay protected.

How do I size a heater?

Start with the heat your process needs, in kcal/hr or kW, including the start-up load. Then note the oil temperature you need, the fuel you can use, the process equipment and the space. Send what you know and our engineers will work out the rest.

How often should the thermic oil be checked?

Have the oil tested in a laboratory at regular intervals, as the oil maker recommends, and watch for changes in colour, viscosity and flash point. Good oil care extends oil life and protects the coil.

Sources: ASME | ISO

Tell us your heat load. We will size your heater.

Share heat load, oil temperature, fuel and process – get a heater recommendation and price within one working day.

Request your free quote

Step 1 of 2 · takes 30 seconds
What do you need?

How much heat do you need? (kcal/hr, if you know)

No spam · reply within one working day

Where should we send your proposal?

Prefer to talk? +91 99090 33851 · WhatsApp

Ready when you are

Thermic oil heaters engineered for your heat load.

Tell us your heat load, temperature and fuel – get a heater recommendation within one working day.

Chat with us
Secure form

Get your heater quote

Step 1 of 2 · takes 30 seconds
What do you need?

How much heat do you need? (kcal/hr, if you know)

No spam · reply within one working day

Where should we send your proposal?

Prefer to talk? +91 99090 33851 · WhatsApp

SSL-encrypted. Your details go only to our engineers – never shared or sold.